Please visit and navigate to Support \ Tools \ Software to download the update utility. Please make sure to download and apply the latest protocol adapter firmware (version 736). Pentair customers with IntelliTouch, EasyTouch, and EasyTouch PL4/PSL4 pool/spa control systems that want to use their iPhone/iPad/iPod touch or Echo devices must purchase the ScreenLogic interface kit (PN 522104) available from your local pool equipment retailer. Download this free app and check out the new interface on our live demo! Control your pool and spa from a local Wi-Fi network, or control remotely over the Internet. You can now also use our Alexa Skill to control your EasyTouch or IntelliTouch system. Pentair's ScreenLogic Connect is a convenient interface for your pool and spa, designed specifically for the iPhone, iPod touch, iPad and Apple Watch. Verify the wiring to the protocol adapter and IntelliTouch Load Center.ScreenLogic is the best selling pool and spa control interface in the industry and allows EasyTouch and IntelliTouch system control on a wide variety of smart devices.

You canunplug and plug back in the wireless router to reset it.ģ. Cycle the power to both of these devices.You can use a paper clip to reset the Protocol Adapter by pressing the recessed reset button. These two devices should be located near one another. Verify the wireless router Power LEDin on. Locate your ScreenLogic2 Protocol Adapter and wireless router.

If step 1 does not fix this issue, go to step 2.Ģ. The Tablet reboot process will take approximately 20 seconds.ī. Wireless Tablet – Press the Suspend button located on the left-side of the Tablet for approximately 4seconds. In most cases, theeasiest way to re-establish a connection is to perform a cold boot of the ScreenLogic2 device:Ī. Make sure your wireless ScreenLogic2 device is connected to your wireless router. If ScreenLogic2has been previously working without a problem, try the following steps to resolve the problem:ġ. If the Configuration program displays “Looking for controller,” for longer then 60 seconds when you startIntelliTouch ScreenLogic2, this may indicate a communication problem somewhere in the system.

Why does the Configuration program say “Looking for Controller”? 1.1 (which will then break all your other network devices connections) however then once the ScreenLogic was connected you could then change the gateway address in ScreenLogic settings back to use the homes gateway of 192.168.0.1. 0.1 so the fix was to go into the home router settings and change it to use 192.186. There was a similar post about the ScreenLogic not being able to connect through the OPs home network, and it was due to the ScreenLogic having a default gateway (network address) setting of 192.168.1.1 For some reason the ScreenLogic reset itself to its default settings.